AARON 900 HIGH FREQUENCY DESICCATOR
Description
Change Power In One Step, Not Four 
The Aaron 900™ high frequency desiccator forever removes the need to go through a tedious multi-step process to change from low to high power. The 900’s digital power control system allows you to change from low to high by simply rotating the power control knob or pushing the up/down buttons on the handpiece. 
Good News For Foot Control 
If you need to use a foot control just plug it in. There is no need to purchase an expensive separate handpiece for foot control situations. The same auto-clavable handpiece that normally operates the unit allows for foot control activation and still retains the ability to activate the unit or adjust the output power via the up/down buttons. 
Digital Error Detection 
Means unsurpassed safety for you and your patient. The Aaron 900 continuously monitors every aspect of the Aaron 900’s output. At the sign of any problem the machine instantly disables the output and displays the appropriate error code on the display. 
Quality & Economy Without Compromise 
A major part of the goal in designing the Aaron 900 was not just to make the best high frequency desiccator, it was to do it at a lower cost; not only at the time you purchase the unit but every day and for many years to come. Therefore you will find the disposable and reusable accessories you use with the Aaron 900 will cost you less too. 
Additionally, everything from the disposable Dermal Tips to the Aaron 900 itself comes with our 100% satisfaction guarantee. 
Features
Go from low to high power by rotating the power control knob or pressing the up/down buttons on the handpiece. No separate ports, no switching plugs. 
Rotary power-control dial provides smooth, rapid power adjustments. 
Autoclavable 3-button handpiece holds standard 3/32" (0.24cm) electrodes safely and securely. 

Output Power Monopolar - 30 Watts
Bipolar - 30 Watts
Line Voltage A900: 120 VAC ± 10%
A900-220: 240 VAC ± 10%
Output Frequency 550 kHz
Line Frequency 50-60 Hz
Dimensions and Weight Width: 22.2 cm (9")
Height: 15.9 cm (6.25")
Depth: 11.4 cm (4.5")
Weight: < 2.3 kg (< 5 lbs.)
Warranty (Unit) - 2 Years
AARON 950 HIGH FREQUENCY DESICCATOR
Description
Change Power In One Step, Not Four 
Introducing the Aaron 950, the first High Frequency Desiccator with Cut. You might call it a split personality. One half of the unit is a high frequency desiccator, out of the mold of our very popular Aaron 900. The other half is a Bovie® Generator, giving you 60 watts of cutting power and coag capabilities – plenty of power for LLETZ/LEEP or most any cutting procedure performed in the doctor’s office.
3-Button Pencil
The three button pencil is a masterpiece of engineering. It allows you to adjust the power output up and down as well as to activate the unit, even when you are in foot control mode!
Designed For Years of Trouble-Free Use
The Aaron 950 is designed and engineered to be the most reliable and durable generator available today. The unit’s life is prolonged by incorporating the latest in chip technology and reducing the number of internal parts, thereby generating less internal heat. Unit cleanup is simplified by its non-absorbing, nonstaining, high-impact ABS enclosure.
Compact, Mobile, Electrosurgical System
Standard package includes the unit, power cord, reusable handpiece, 10 handpiece drapes, five disposable active electrodes, 50 sharp dermal tips, 50 blunt dermal tips, one reusable dispersive cord, five disposable dispersive electrodes, user’s guide, and wall-mount kit.
Bovie® Generator 
• 60 Watts – Cut, Blend, Coagulation 
• Isolated Power 
• 6 Presets – For The Doctor’s Favorite Settings 
The Generator 
The left half of the unit is a Bovie generator. It is a floating ground unit that requires a return electrode pad to be used. This isolated power feature helps to ensure your safety as well as that of the patient. 
Three Modes of Operation 
The Bovie Generator offers you up to 60 watts in Cut mode, Blended Cut mode, and Pinpoint Coagulation mode. 
Simplicity is achieved using easy-touch, color-coded membrane pads, and by placing all user controls and outputs on the unit’s compact front panel. 
Six Presets 
The six available presets labeled “A-F” allow the user to record often used settings for one touch recall. Each preset stores the mode selection and power setting for one operating mode. 

Output Power -  Generator Cut: 60 watts 
Blend: 60 watts 
Coagulation: 60 watts 
High Frequency Desiccator Fulguration: 35 watts 
Bipolar: 30 watts
Line Voltage A950: 120 VAC ± 10% 
A950-220: 230-240 VAC 
Output Frequency 350-800 kHz
Line Frequency 50-60 Hz
Dimensions & Weight Width: 26 cm (10.25") 
Height: 17.8 cm (7") 
Depth: 11.4 cm (4.5") 
Weight: < 3.7 kg (< 8 lbs.) 
Warranty Unit - 2 years
AARON 950 HIGH FREQUENCY DESICCATOR
Description
Change Power In One Step, Not Four 
Introducing the Aaron 950, the first High Frequency Desiccator with Cut. You might call it a split personality. One half of the unit is a high frequency desiccator, out of the mold of our very popular Aaron 900. The other half is a Bovie® Generator, giving you 60 watts of cutting power and coag capabilities – plenty of power for LLETZ/LEEP or most any cutting procedure performed in the doctor’s office.
3-Button Pencil
The three button pencil is a masterpiece of engineering. It allows you to adjust the power output up and down as well as to activate the unit, even when you are in foot control mode!
Designed For Years of Trouble-Free Use
The Aaron 950 is designed and engineered to be the most reliable and durable generator available today. The unit’s life is prolonged by incorporating the latest in chip technology and reducing the number of internal parts, thereby generating less internal heat. Unit cleanup is simplified by its non-absorbing, nonstaining, high-impact ABS enclosure.
Compact, Mobile, Electrosurgical System
Standard package includes the unit, power cord, reusable handpiece, 10 handpiece drapes, five disposable active electrodes, 50 sharp dermal tips, 50 blunt dermal tips, one reusable dispersive cord, five disposable dispersive electrodes, user’s guide, and wall-mount kit.
Bovie® Generator 
• 60 Watts – Cut, Blend, Coagulation 
• Isolated Power 
• 6 Presets – For The Doctor’s Favorite Settings 
The Generator 
The left half of the unit is a Bovie generator. It is a floating ground unit that requires a return electrode pad to be used. This isolated power feature helps to ensure your safety as well as that of the patient. 
Three Modes of Operation 
The Bovie Generator offers you up to 60 watts in Cut mode, Blended Cut mode, and Pinpoint Coagulation mode. 
Simplicity is achieved using easy-touch, color-coded membrane pads, and by placing all user controls and outputs on the unit’s compact front panel. 
Six Presets 
The six available presets labeled “A-F” allow the user to record often used settings for one touch recall. Each preset stores the mode selection and power setting for one operating mode. 

Output Power -  Generator Cut: 60 watts 
Blend: 60 watts 
Coagulation: 60 watts 
High Frequency Desiccator Fulguration: 35 watts 
Bipolar: 30 watts
Line Voltage A950: 120 VAC ± 10% 
A950-220: 230-240 VAC 
Output Frequency 350-800 kHz
Line Frequency 50-60 Hz
Dimensions & Weight Width: 26 cm (10.25") 
Height: 17.8 cm (7") 
Depth: 11.4 cm (4.5") 
Weight: < 3.7 kg (< 8 lbs.) 
Warranty Unit - 2 years
AARON 1250 HIGH FREQUENCY DESICCATOR
Description
The Aaron 1250™, by Bovie®, features Cut, Blend, Coagulation, Fulguration, and Bipolar modes. Bovie incorporates automatic safety features into the Aaron 1250 like self-test circuits, audible tones, discreet outputs, isolated circuitry, and Bovie NEM™ (neutral electrode monitoring). 
The Aaron 1250 by Bovie is a multipurpose electrosurgical generator for use in the modern physician's office and surgi-center. It features both monopolar and bipolar functions to satisfy all of your surgical demands with safety, flexibility, reliability, and convenience. 
Bovie's major goal in designing the Aaron 1250 was to deliver the absolute highest level of safety and quality. One major area of savings can be found in the output power of 120 watts. Nearly every hospital specification on an electrosurgical generator calls for 300 watts of power. Have you ever asked yourself why you need 300 watts at all stations when it is used so infrequently? We did. It results in spending a few thousand dollars more per unit for a feature that just is not used. 
Convenient Display Features 
For your convenience, the power output of the Aaron 1250 is calibrated in watts with large, illuminated digital displays. The Aaron 1250 remembers its last used settings; so when you turn the unit on, it performs a safety system check and automatically powers up to those settings. 
Coagulation Modes 
The Aaron 1250 offers two levels of coagulation: pinpoint and fulguration. Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration (spray) coagulation provides greater control of bleeding in highly vascular tissues over broad surface areas. 
Designed for Safety 
Electrosurgical safety is a combination of good equipment design and safe surgical practices. The Aaron 1250, as part of this combination, represents state-of-the-art design using the latest in digital technology. 
Bovie incorporates automatic safety systems into the Aaron 1250 like self-test circuits, audible tones, discreet outputs, and isolated output circuitry. 
BovieNEM™ and BovieGuard™ means safety is digitally designed inside. The FCFS™ (first come, first served) discrete output design of the Aaron 1250 enhances safety by allowing only one output to be activated at any given time. This feature ensures that only the device you first activate will be an active device. Secondary commands will not override the first command. 
Large illuminated digital displays
Rotary power-control dial provides smooth, rapid power adjustments. 
Five Output Modes: 
Cut (120 Watts), Blend (90 Watts), Coagulation (Pinpoint 80 Watts), Fulguration, (Spray 40 Watts), Bipolar (30 Watts) 
Self-test circuits, Audible tones, Discreet outputs (FCFS™ - First Come First Served)  Isolated circuitry BovieNEM™ (Neutral Electrode Monitoring), Digital Error Detection 

Output Power -  Generator Cut: 120 watts
Blend: 90 watts
Coagulation: 80 watts
Fulguration: 40 watts
Bipolar: 30 watts
Line Voltage A1250: 120 VAC ± 10%
A1250-220: 220 VAC ± 10%
Output Frequency 350-800 kHz
Line Frequency 50-60 Hz
Dimensions & Weight Width: 26.04 cm (10.25")
Height: 15.24 cm (6")
Depth: 29.85 cm (11.75")
Weight: < 5.5 kg (< 12 lbs.)
Warranty Unit - 2 years
                                                                                                                                                            

 

[Home] | [About us] | [Products] |  [Rentals] |  [Contact Us]